6. Function blocks
6.1 Manufacturer function blocks
Function block outputs
Description Note
(bit)
AC
1: Signals an ongoing positioning job
Pulses are output at device output Q1 or Q2.
also during jog mode or during the braking
ramp and also after S_ is set to 0.
0: Signals that there is no ongoing positioning
job.
E1
Error output
1: in the event of incorrect parameters, such
as:
- FO < FS
(operating frequency < start frequency)
- PF < FS
(jog frequency < start frequency)
No positioning commands if the function
block detects incorrect parameters.
If the function block detects an incorrect
parameter change during an active pos-
itioning job, the step sequence frequency
is reduced according to the braking ramp
and the motor is gently braked to a stop.
(DWord)
QV
Actual number of steps completed
Integer value range:
0…+2147483647
QF
Actual output frequency
Integer value range:
0…5000 Hz
Assigning operands
You can assign the following operands to the function block outputs that are numeric
outputs:
Assigning operands Value outputs
MB, MD, MW – Markers
x
NB, NW, ND – NET markers
2)
NET station n
x
QA – Analog output
x
I – Value input of a FB
x
2)
Only on projects with ≥ 2 base devices on NET
You can assign the following operands to the function block outputs that are bit out-
puts:
Assigning operands Bit outputs
M - Markers
x
SN – Output bit via NET (send)
2)
SN - Output
bit via NET (send)
x
N – Network marker bit
2)
x
LE – Output backlight
x
Q – Bit output
x
I – Bit input of a FB
x
2)
Only on projects with ≥ 2 base devices on NET