Appendix
A.3 Technical data
Electromagnetic compatibility (EMC)
Overvoltage category/pollution degree

Overvoltage category/pollution
degree III/2
Electrostatic discharge (ESD)

according to IEC EN 61000-4-2
Air discharge

8kV
Contact discharge
Generation

EASY-E4-UC-12RC1
01
4kV
 from 02
6kV
EASY-E4-UC-12RCX1
01
4kV
 from 02
6kV
EASY-E4-DC-12TC1
01
4kV
 from 02
6kV
EASY-E4-DC-12TCX1
01
4kV
 from 02
6kV
EASY-E4-AC-12RC1
from 01
6kV
EASY-E4-AC-12RCX1
from 01
6kV
EASY-E4-UC-8RE1
01
4kV
 02
4kV
 from 03
6kV
EASY-E4-UC-16RE1
01
4kV
 02
4kV

from 03
6kV
EASY-E4-DC-4PE1
from 01
6kV
EASY-E4-DC-6AE1
01
4kV
 02
4kV

from 03
6kV
EASY-E4-DC-8TE1
01
4kV
 02
4kV

from 03
6kV
EASY-E4-DC-16TE1
01
4kV
 02
4kV

from 03
6kV
EASY-E4-AC-8RE1
from 01
6kV
EASY-E4-AC-16RE1
from 01
6kV
The contact discharge value for all EASY-E4-..-....1P devices with push-in
terminals is 6 kV.
Electromagnetic fields (RFI)
according to IEC EN 61000-
4-3
0.8 - 1.0 GHz: 10 V/m
1.4 - 2 GHz: 3 V/m
2.0 - 2.7 GHz: 1 V/m
Radio interference suppression
In accordance with EN
61000-6-3
Class B
Burst
according to IEC/EN 61000-
4-4
Supply cables: 2 kV
Signal cables: 2 kV
easyE402/24 MN050009ENEaton.com