3 Installation
3.2 Mounting
DC1 variable frequency drive 12/13 MN04020003Z-EN www.eaton.com 49
Insert a plastic gland into the knockout on the left – which will already have
been punched out at the factory – in order to thread in the power supply
cord. Due to EMC reasons, you should use an EMC cable gland in the
knockout on the right in order to connect the motor cable screen across a
large area and ground it.
Figure 28: Installing the cable glands
Table 5: Usable cable glands
Make sure that the cable glands have at least an IP66 degree of
protection.
L2N
L3
U
V
W
L1N
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10 11
Range Size Hole size PG
gland
Metric
gland
Part no.
Plastic
1)
Part no.
Metal/EMC
1)
Control
section
FS1 2 x 22 mm 2 x PG 13.5
1 x PG 16
2 x M20
1 x M25
M20:
GHG9601955R0003
and
GHG9601941R0033
M25:
GHG9601955R0004
and
GHG9061941R0034
M20:
CAP189202 (6 - 13 mm)
or
CAP189552 (4.5 - 10 mm)
and
DKA12E
M25:
CAP189252 (10 - 18 mm)
or
CAP189562 (6 - 13 mm)
and
DKA13E
FS2
FS3
Power
section
FS1
3 x 22 mm 3 x PG 13.5 3 x M20
FS2 1 x 22 mm
2 x 25 mm
1 x PG 13.5
2 x PG 16
1 x M20
2 x M25
FS3
1) Part nos. for glands available from Cooper Crouse-Hinds GmbH provided as an example