Sensors and overheating thermostats
Service
manual
46
Outlet air - Overheating thermostat
Electric, gas and steam heated dryers
Function
Theoutletairoverheatingthermostatislocatedontheoutletpipeatthebackofthe
dryer.
Theoverheatingthermostatensuresthatthedryerdoesnotoverheatduringprogram
operation.
Thethermostatopensautomaticallyandhastoberesetmanually.
Resetting
1.Disconnectthepowersupplytothedryer.
2Removebottombackplate.
4.Fig.1ThethermostatcannowberesetmanuallybypressingtheresetbuttonA
onthethermostat.
Error code
Thefollowingerrorcodeisrelatedtothissection:
E08
SeeSelectaControlServiceManualformoreinformation.