Motor
Service
manual
58
Motor and transmission
Fig. 1 Fan module A and Transmission module B.
Thedryerhastwomotors,oneforthefanandoneforthedrum.
Bothmotortypesareprotectedbythermaloverloadrelays.
Ifamotoroverheats,thethermaloverloadrelayisswitchedoffandthecontroldisplays
anerrorcode.
Theoverheatprotectionre-closesautomaticallywhenthemotorcoolssufficiently.The
dryercanthenbere-started.
Themotorsarelocatedatthebackofthedryer.
Note! Onelectricheateddryerstheinternalcontrolisprotectedwithsafetyfuses.See
nextpage.
Before replacing the motor
Itisimportanttocomparethedatasignonthenewmotorwiththeoneontheoldmotor
regardingvoltageandrpm.
Error code
Thefollowingerrorcodeisrelatedtothissection:
E05 Motor, blower (A)
E06 Motor, drum (B)
SeeSelectaControlServiceManualformoreinformation.