7.2.2 Using External Amplitude Control
When External Amplitude Control is enabled, the front panel amplitude control is disabled
and the LCD displays three dashes (see Figure 7.2 LCD when in External Amplitude
Control Mode below).
Figure 7.2 LCD when in External Amplitude Control Mode
The ultrasonic amplitude can be controlled using one of the two analog input pins on the
user I/O connector (pins 17 and 18). For information on configuring the power supply user
I/O refer to your DCX S Power Supply Web Page Interface Instruction Manual (100-412-
187).
7.2.3 Using the Web Page Interface
The ultrasonic amplitude can be set to a user specified value using the web page interface.
For more information, refer to your DCX S Power Supply Web Page Interface Instruction
Manual (100-412-187).