60 100-412-183 REV. 13
5.3.11 Available Analog Output Functions
Table 5.9 Available Analog Output Functions
Function Description Valid Range
Amplitude Out
Provides a 0 V to 10 V output signal
proportional to amplitude (0% to 100%).
0 V to 10 V
(0% to 100%)
Power Out
Provides a 0 V to 10 V output signal
proportional to ultrasonic power output (0%
to 100%).
0 V to 10 V
(0% to 100%)
Frequency Out
Provides a 0 V to 10 V output signal that
indicates relative frequency in memory. Actual
frequency depends on the power supply
operating frequency:
0 V to 10 V
(5 V is zero offset)
Frequency
Lower
Limit (0 V)
Upper Limit
(10 V)
20 kHz 19,450 Hz 20,450 Hz
30 kHz 29,250 Hz 30,750 Hz
40 kHz 38,900 Hz 40,900 Hz

Table of Contents