7.3 Resetting the Power Supply Alarms
You need to reset the weld system when you get an overload. When there is an overload,
the alarm icon appears on the front panel LCD and the General Alarm output on the user
I/O connector becomes active. The procedure for resetting the power supply depends on
the power supply alarm settings. Refer to Table 7.2 Resetting the DCX S Power Supply for
reset procedures.
For more information on interfacing the DCX S Power Supply using the user I/O
connections refer to 5.3.6 User I/O Connections in Chapter 5: Installation and Setup.
Table 7.2 Resetting the DCX S Power Supply
Alarm Setting Reset Procedure
Latching Alarms
Press the front panel Reset key. You can also send an External
Reset signal.
Non-Latching Alarms Remove and re-apply the start signal.
NOTICE
Alarm circuitry requires at least 20 ms before restarting ultrasonic
power.