100-412-183 REV. 13 99
7.5.2 Frequency Bar-Graph Interpretation
The actual frequency depends on the power supply’s operating frequency. Use Table 7.6
to Table 7.8 below to interpret frequency bar graph readings.
NOTICE
If there is a test overload or an external memory reset signal is
received, then the 50% segment will be displayed and blinking.
Table 7.6 Frequency Bar-Graph Interpretation - 20 kHz (50 Hz Segment)
20 kHz (50 Hz/Segment)
19,475–19,524
19,525–19,574
19,575–19,624
19,625–19,674
19,675–19,724
19,725–19,774
19,775–19,824
19,825–19,874
19,875–19,924
19,925–19,974
19,975–20,024
20,025–20,074
20,075–20,124
20,125–20,174
20,175–20,224
20,225–20,274
20,275–20,324
20,325–20,374
20,375–20,424
20,425–20,474
1
2
3
4
5 (25%)
6
7
8
9
10 (50%)
11
12
13
14
15 (75%)
16
17
18
19
20 (100%)
Table 7.7 Frequency Bar-Graph Interpretation - 30 kHz (76 Hz Segment)
30 kHz (76 Hz/Segment)
29,278–29,353
29,357–29429
29,430–29,501
29,502–29,581
29,582–29,657
29,658–29,733
29,734–29,809
29,810–29,885
29,886–29,961
29,962–30,037
30,038–30,113
30,114–30,189
30,190–30,265
30,266–30,341
30,342–30,417
30,418–30,493
30,494–30,569
30,570–30,645
30,646–30,721
30,722–30,797
1
2
3
4
5 (25%)
6
7
8
9
10 (50%)
11
12
13
14
15 (75%)
16
17
18
19
20 (100%)
Table 7.8 Frequency Bar-Graph Interpretation - 40 kHz (100 Hz/Segment)
40 kHz (50 Hz/Segment)
38,950–39,049
39,050–39,149
39,150–39,249
39,250–39,339
39,350–39,449
39450–39,549
39,550–39,649
39,650–39,749
39,750–39,849
39,850–39,949
39,950–40,049
40,050–40,149
40,150–40,249
40,250–40,349
40,350–40,449
40,450–40,549
40,550–40,649
40,650–40,749
40,750–40,849
40,850–40,949