100-412-183 REV. 13 49
5.3 Installation Steps
Basic installation notes:
• To avoid problems associated with EMI, you should route high power lines (AC and Ultrasonic RF)
away from low power lines (controls signals)
• You should consider future troubleshooting and repair when installing all wiring. All wiring should
be either color coded or tagged with industrial wire tags
• The minimum cable bend radius is 5 times the cable outer diameter for RF cables
• The minimum cable bend radius is 10 times the cable outer diameter for user I/O & Ethernet
cables
• Ground wires should not be shared with other equipment
• All inductive coils must be suppressed with appropriate devices, such as diodes or RC networks
WARNING High Voltage Hazard
To prevent the possibility of an electrical shock:
• Ensure the power source is disconnected before beginning work on line
connections
• Ensure the power switch on the back of the unit is in the OFF position
before making any electrical connections
• Always plug the power supply into a grounded power source
• To prevent the possibility of an electrical shock, ground the power supply
by securing an 8 gage grounded conductor to the ground screw located
next to the air outlet
• Ensure power supply installation is performed by qualified personnel and
in accordance with local standards and regulations