EasyManua.ls Logo

Emerson DCX S - Table 8.7 Stud Torque Values

Emerson DCX S
154 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
100-412-183 REV. 13 119
8.2.3 Stud Torque Values
* Add a drop of Loctite 290 threadlocker to the stud. Torque and let cure for 30 minutes before using.
8.2.4 Routine Component Replacement
The lifetime of certain parts is based on the number of cycles the unit has completed, or
on hours of operation. Change cooling fans at 20,000 hours, and filter kits as required.
Table 8.7 Stud Torque Values
Used on Stud Size Torque EDP #
20 kHz
1/2 in x 20 x 1-1/4 in
450 in·lb, 50.84 N·m
100-098-370
1/2 in x 20 x 1-1/2 in 100-098-123
30 kHz 3/8 in x 24 x 1 in 290 in·lb, 32.76 N·m 100-298-170R
40 kHz* M8 x 1.25 70 in·lb, 7.91 N·m 100-098-790

Table of Contents