96 100-412-183 REV. 13
7.4.1 Power Supply Registers
Table 7.4 Power Supply Registers
Register Description
Read
Only
Min.
Value
Max.
Value
Default
Value
0 -100 Unused
101 LCD Software version Yes 0 999 N/A
102
Bar graph identification after weld
complete
0
(power)
1
(freq)
0
(power)
103 Latching Alarms (reset required) 0 = OFF 1 = ON 0 = OFF
104
External amplitude control - user
analog input
0 = OFF 1 = ON 0 = OFF
105 Start ramp time (ms) 1 999 80
106 Store frequency at end of weld 0 = OFF 1 = ON 1 = ON
107
Power-on seek/scan (0 = off, 1 =
seek, 2 = scan)
0 = OFF 2 1 = seek
108 Seek ramp time (ms) 1 999 80
109 Timed seek (every 60 seconds) 0 = OFF 1=on 0 = OFF
110 Seek time (ms) 1 999 500
111 Frequency offset 0 = OFF 1 = ON 0 = OFF
112 Reserved Yes 0 0 0
113 Reserved Yes 0 0 0
114 Reserved Yes 0 0 0
115
Restore defaults (0 = off, 1 = Weld
Presets Only,
2 = All System Defaults)
0 = OFF 2 0 = OFF
116 IP address - 1 Yes 0 255 192
117 IP address - 2 Yes 0 255 168
118 IP address - 3 Yes 0 255 10
119 IP address - 4 Yes 0 255 100
120 Gateway for IP address 1 Yes 0 255 -
121 Gateway for IP address 2 Yes 0 255 -
122 Gateway for IP address 3 Yes 0 255 -
123 Gateway for IP address 4 Yes 0 255 -
124 Subnet Mask for IP address 1 Yes 0 255 255
125 Subnet Mask for IP address 2 Yes 0 255 255
126 Subnet Mask for IP address 3 Yes 0 255 255