EasyManua.ls Logo

Emerson DCX S - Table 4.1 Environmental Specifications; Table 4.2 Electrical Input Operating Voltages

Emerson DCX S
154 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
34 100-412-183 REV. 13
4.1 Technical Specifications
4.1.1 Environmental Specifications
The DCX S Power Supply has the following environmental specifications:
4.1.2 Electrical Specifications
The following tables list input voltage and current requirements for the DCX S Power
Supply.
* 200 V Min. for 4 kW units.
NOTICE
All specifications are subject to change without notice.
Table 4.1 Environmental Specifications
Environmental Condition Acceptable Range
Ambient Operating Temperature +41° F to +104° F (+5° C to +40° C)
Storage / Shipping Temperature -13° F to +131° F (-25° C to +55° C)
Humidity Maximum 95%, non-condensing
IP Rating 2X
Table 4.2 Electrical Input Operating Voltages
Power Supply Rating Input Operating Voltage
All Models
200 V to 230 V Nominal (180 V Min.* to 253 V Max.), 50 Hz
or 60 Hz, Single Phase.
Table 4.3 Input Current and Circuit Breaker Specifications
Model Power Current Rating
20 kHz
1250 W 7 A Max. @ 200 V / 15 A Breaker
2500 W 14 A Max. @ 200 V / 25 A Breaker
4000 W 25 A Max. @ 200 V / 25 A Breaker
30 kHz
750 W 5 A Max. @ 200 V / 10 A Breaker
1500 W 10 A Max. @ 200 V / 15 A Breaker

Table of Contents