EasyManua.ls Logo

Emerson DL8000 - Chapter 2 - Installation and Use; Housing

Emerson DL8000
330 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DL8000 Preset Instruction Manual
Revised February-2016 Installation and Use 2-1
Chapter 2 0BInstallation and Use
In This Chapter
2.1 Housing.………………………………………………………………………. 2-1
2.1.1 Class I Zone 1 Housing .............................................................. 2-2
2.1.2 Securing the Cover to the Class I Zone I Case .......................... 2-4
2.1.3 Class I Div 2 Housing ................................................................. 2-5
2.2 Card Cage.…………………………………………………………………… 2-6
2.2.1 Backplane ................................................................................... 2-7
2.3 Central Processor Unit (CPU)………………………………………………. 2-8
2.3.1 BInstalling and Removing Wire Channel Covers ..................... 2-10
2.3.2 Removing and Installing Module Covers .................................. 2-11
2.3.3 Removing the CPU Module ...................................................... 2-11
2.3.4 Installing the CPU Module ........................................................ 2-12
2.4 License Keys ……………………………………………………………….. 2-12
2.4.1 Installing a License Key ............................................................ 2-13
2.4.2 Removing a License Key .......................................................... 2-14
2.5 Installation Planning ……………………………………………………….. 2-15
2.6 Mechanical Installation ……………………………………………………. 2-15
2.6.1 Planning Considerations ........................................................... 2-16
2.7 Electrical Installation ………………………………………………………. 2-18
2.7.1 General Considerations ............................................................ 2-18
2.7.2 Field Wiring Installation Guidelines: ......................................... 2-18
2.7.3 Electrical Wire and Cable Selection and Installation ................ 2-19
2.7.4 Input/Output Field Signal Wiring ............................................... 2-20
2.7.5 Electrical Grounds .................................................................... 2-20
2.7.6 Wire Conduit Selection and Installation .................................... 2-22
2.8 Operator Interface …………………………………………………………. 2-23
2.8.1 Keypad ...................................................................................... 2-24
2.8.2 LED Status Indicators ............................................................... 2-25
This chapter describes the DL8000’s external housing, its internal
electronic components (the ROC800-Series CPU), and the specifics of
mechanical and electrical installation.
2.1 1BHousing
The DL8000 uses either of two external housings:
A cast aluminum casing with stainless steel front cover bolts. It is
flame-proof (in accordance with Class I, Zone 1, Group IIB) and
weatherproof (in accordance with IP66).
A 14-gauge stainless steel box with 12-gauge stainless steel
mounting flanges, CSA-rated as a Type 4 enclosure. The door is
made of 0.090 inch thick aluminum secured to the box with a
stainless steel piano hinge and two stainless steel spring latches.

Table of Contents

Other manuals for Emerson DL8000

Related product manuals