EasyManua.ls Logo

Emerson DL8000 - Advance Pulse Module (APM); Fuse Wiring with Multiple AC

Emerson DL8000
330 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DL8000 Preset Instruction Manual
Revised February-2016 Modules 3-23
Figure 3-20. Fuse Wiring with Multiple AC I/O Modules
3.2.13 Advance Pulse Module (APM)
The APM provides advanced functionality commonly found in liquids
and gas measurement programs, including support for densitometer
inputs, detector inputs, pulse inputs, pulse frequencies, and pulse
outputs. Field wiring and DIP switch settings provide this flexibility.
See Figures 3-21 through 3-30.
Note: The DL8000 supports up to nine APMs.
For densitometer inputs, you can designate channel 3 as a pulse input
using a frequency input channel with hardware filtering for the Micro
Motion
®
7835/7845 densitometer. You can designate channel 4 as a
pulse input or a solid state pulse output.

Table of Contents

Other manuals for Emerson DL8000

Related product manuals