DL8000 Preset Instruction Manual
E-12 DL8000 Keypad Display Revised February-2016
E.3 Program Mode
Warning
Using program mode, you can change metrology values on the DL8000.
Consequently, you may need to unlock the Weights & Measures switch
on your DL8000. Consult with your site’s policies and procedures in
case this is necessary.
“Program mode” enables you—with appropriate access authority—to
access and change components of the keypad display program. Access
to program mode is possible through any of several “normal state”
screens (Recipe Selection, Additive Selection, Loading, Preset Quantity,
or Data Entry). Press ALT+ENTER on the keypad to display the
primary program mode screen:
14/02/12 13:58:59
Choose an Option
( EXIT to Quit )
(ENTER to Continue)
Log In
Display Test
About
Note: Example screens in this section show an open (or unlocked)
Weights & Measures icon.
E.3.1 ROCLINK 800 Configuration
You must set DL8000 security to enable an operator ID to access
program mode. Alternately, you may use one of the two personal
identification numbers (PINs) ROCLINK 800 provides to permit
administrative access to the keypad display program.
Start ROCLINK 800 and double-click Display #46, Navigation Setup
from the directory tree.
Figure E-4. Navigation Setup Option