DL8000 Preset Instruction Manual
E-10 DL8000 Keypad Display Revised February-2016
E.2.8 Transaction End Prompt
If the operator selects at least one end transaction prompt, this
screen displays during the transaction end sequence (n indicates the
end transaction prompt).
Note: If you defined multiple transaction prompts, the DL8000
displays all defined end transaction prompts in sequence.
11/23/09 13:58:59
Trans end prompt #n
Recipe #1
(ENTER to continue)
E.2.9 Conditional String Display for Temperature Correction String
When no net volumes appear on the loading screen (either by the
loading method or in the dynamic data), the “Volume corrected to
-------->xx°C/°F” message does not display. This message should
display under any of the following conditions:
If the Preset Delivery Type parameter [63,0,29] is set to 3, Standard
to Volume (see Table E-5 for more information)
If the Type of Display Quantity parameter [63,0,30] is set to 1, Net
Standard Volume (see Table E-5 for more information).
If any of the totalizers configured on the dynamic data displays
([62,0,32] to [62,0,47]) is a net totalizer (see Table E-4).