DL8000 Preset Instruction Manual
Revised February-2016 DL8000 Keypad Display E-9
Table E-3 lists the possible status messages that could display on the
Loading screen during various stages during the load:
Table E-3. Loading Screen Status Messages
Message Description
Start to Load Press Start key to start loading
Line Pack delay Indicates the pump for the component is running
and loading line is being packed.
Load in Progress Indicates the batch delivery is in progress in a
normal manner.
Shutting Valve Indicates that all open flow control valves are
closing
Pump Stop Delay Waiting for pump to close; flow control valve is
already closed
Batch Halt Indicates current batch is halted
Alarm Halt Indicates current batch halted due to alarm
Transaction Ended Indicates transaction has ended
Batch Aborted Indicates batch has aborted
Batch Ended Indicates batch has ended
Batch Complete Indicated batch has completed after batch
archiving
Opening BV Indicates the block valve for the component is
being opened
Archiving Batch Indicates batch data is being archived
Archiving Transac Indicates that transaction data archiving is
occurring
Printing Ticket Indicates the ticket is being printed
CRC Fail, Wait Indicates the integrity check for user program
images has failed
Prebatch Testing Indicates the integrity check for user programs is
running
According to Industry Canada standard requirements, the display
test executes before actual loading starts. This test switches on and
off every pixel of the display (Left and Right screen). The separating
line between displays remains as it.
The display test executes only when the parameter “Display test on
batch start” [TLP 62,0,185] is Enabled (set to 1)
If enabled, the test executes in both manual and auto modes.