DL8000 Preset Instruction Manual
D-90 Communications Protocols Revised February-2016
D.12 Error Codes
Following are error codes for the DL8000 protocol.
Table D-8. Error Codes
Error Code [63,0,95] Reasons
No Error
Invalid recipe number
2
Incorrect delivery sequence or low proportion
3
Incorrect component ratios. This exception is
raised if either of the following conditions is not
satisfied.
Total of component ratios of all components
configured in the recipe must equal 100%.
The component ratio of components not
present in the recipe must be zero.
4
Invalid meter ID of a component used in the
recipe.
5
Invalid valve ID, associated with a meter used by
component used in the recipe.
6
Invalid primary component.
7
Target flow rate too low.
Target flow rate too high.
9
Incorrect side stream mask
10
Preset is not in the range of minimum and
maximum preset.
11
Tolerance Allowed is no and blend ratio is out of
the tolerance after considering the clean line
quantity.
12
Number of batches delivered in current
transaction is more than configured limit of
maximum number of batches per transaction.
13
Transaction Total is greater than maximum
transaction limit.
14
Archive configuration error.
15
Invalid additive selection.
16
Invalid preset additive option.
17
Invalid additive type.
18
Insufficient component preset.
19
Exceeded additive limit.
20
Reverse meter configured and delivery type not
MAS
21
Reverse meter configured and unit type not
sequential (auto/manual)