DL8000 Preset Instruction Manual
D-14 Communications Protocols Revised February-2016
In the DanLoad 6000 protocol, the TAS uses the Transaction Data by
Component command (hex 0x1F) to obtain transaction data (transaction
volumes, meter totals, data items, etc.) from the DL8000.
D.2.5 Batching Status States
The Batching Status parameter [63,0,9] maintains various process
values which the TAS uses to monitor the status of both the DL8000
and the overall batching operation.
Note: These values accumulate in the TLP and do not currently appear
on any system report or screen.
0 Idle
1 Select_Recipe
2 Invalid_Recipe
3 Enter_Preset
4 Invalid_Preset
5 Batch_Auth
10 Alarm_Batch_Halt
12 User_Batch_Halt
13 Batch_Complete
20 Start_Pump Ratio blending only
21 Line_Pack
22 Wait_for_Line_Pack
23 Flow_Control
24 Valve_Close
25 Pump_Stop_Delay
26 Wait_for_Pump_Stop
27 Stop_Pump
28 Wait_All_Stop
29 Batch_Halt
30 Next_Component Sequential blending only
31 Line_Flush
32 End_of_Batch
33 Wait_Full_Valve_Close
34 Close_Block_Valve
37 End_Batch
38 End_Transaction
50 Select_Additive
60 Archive_Transaction