DL8000 Preset Instruction Manual
E-6 DL8000 Keypad Display Revised February-2016
Note: With a failure of either power or communications, the preset
terminates the application selected with program mode.
The system displays this screen when communications fail between the
DL8000 and the keypad display:
Communication lost:
Connect to Continue
Note: You cannot resolve this communication failure from the
keypad. You must use ROCLINK 800 to access the DL8000
and verify that the Keypad Display program is running, that
port 2 is assigned to the LCD, and that the baud rate is
57.6K.
E.1.5 Operational Modes
The preset has two operational modes: loading and program. Loading
mode enables operators to load product. Program mode provides access
to more functions, including the ability to modify parameters within the
preset. The security functions within the preset enable you to determine
which system IDs can access which modes and functions. For further
information on security, refer to Section E.3, Program Mode.
E.2 Loading Mode
“Loading mode” is the normal mode of DL8000 operations. You use
loading mode to perform all loading activities (such as batching,
blending, and additive injections).
The following screens show the screen sequences during normal batch
setup and delivery operations.
Note: Since you can easily change the content of the DL8000 displays,
the screen in this section are only examples and may not
correspond exactly to the appearance of the displays on your
DL8000s.
E.2.1 Recipe Selection
All configured recipes display in the Recipe Selection screen. The
operator selects one of the recipes.