DL8000 Preset Instruction Manual
Revised February-2016 DL8000 Keypad Display E-25
(TLP)
Parameter accepts a TLP value [0,0,0]. To define a TLP, press
SELECT. The system displays valid IO module values. Press
ENTER to define a module. (If you select a module which is not
installed the message Req. Card not in Sys displays). The system
prompts you to choose a logical. Press SELECT to page through the
available values and press ENTER to choose a value. As soon as the
system validates your selection, it prompts you to select a parameter.
Press SELECT to page through the available values and press
ENTER to choose a value. Press ALT+ENTER to cancel a
selection while in data entry mode.
Note: WM displays in the last line of the right-hand screen if the
selected parameter is a Weights & Measures parameter and the
Weights & Measures switch is locked. In this case, you cannot
edit this parameter.
Value
If you make an error during data entry, either press CLEAR (to clear
the entire entry) or use the BSKP key (ALT+SELECT) to clear just the
last character entered. While you are entering data, you can restore the
previous value by pressing ALT+ENTER.
To enter AAA, press and hold down ALT. Press 1. The display first
shows a decimal point, then A. Repeat the process twice.
To enter ABC, press and hold down ALT. Press 1 twice. Wait a second,
and press 1 three times. Finally, press 1 four times.
Note: Pressing and holding down ALT and any key quickly displays
all the values sequentially for that key (., A, B, and C in the case
of the 1 key). Until you get used to the scroll speed, it is better to
press the keys individually to make sure you have the right
values.
A parameter group has parameters from a single point type. If the
parameter is from different point type, then the display shows the point
type name from last parameter only for whole screen
Table E-7 shows the menus, sub menus, and associated parameters
under Setup/Configuration.