DL8000 Preset Instruction Manual
E-46 DL8000 Keypad Display Revised February-2016
Enter Type
Enter Logical
Enter Parameter
ENTER to Continue
0
0
0
UP | DOWN
Press to access each value. Once you define the TLP, press Enter to
save your changes. The program validates the TLP you have entered.
(Press ALT+CLEAR to exit the Direct TLP access screen.)
If the TLP is valid, the program displays the current value of the TLP
and indicates the parameter’s read/write attribute.
TLP Entered
Current value
Param Attribute
ENTER to Continue
63 0 12
0
Read Write Cndl
If the parameter’s attribute is read/write or read/write conditional (and
the W&M switch is unlocked), the ENTER to Continue message at the
bottom of the screen indicates that you may enter a new value for the
TLP.
If the parameter is read-only, only the EXIT to Go Back message
displays at the bottom of the screen.
If the TLP you specify is invalid, the program displays the following
screen:
TLP Entered
Invalid TLP Entry
Press ALT+CLEAR to exit this screen and redisplay the parameter
entry screen.
If the TLP is read/write or read/write conditional and the W&M switch
is locked, the program displays the following message: