DL8000 Preset Instruction Manual
E-52 DL8000 Keypad Display Revised February-2016
Enter Prover Qty.
ENTER to continue)
10
Once you provide a prover volume and press ENTER, the system
displays a meter factor:
Current MF
Corrected Qty
Additive Units
New MF
Avg. MF
(ENTER to update)
1.000000
0.000000
CC
0.000000
0.00000
You can either accept the displayed current meter factor or press STOP
to reject it. If you press STOP, the system rejects the new meter factor
and retains the old meter factor. If you press ENTER, the system
updates the Additive Meter Factor parameter [67,X,28] and displays the
following screen:
Enter Adtv M-Factor
(ENTER to accept)
1.1
Press ENTER to accept and update the additive’s meter factor. The
Additive Calibration screen displays:
Select Additive
# of Injections
LEFT | RIGHT
Enter Additive Qty.
Enter Calib. Delay
Additive 1
Press EXIT to exit the additive calibration process and return to the
Calibration menu: