DL8000 Preset Instruction Manual
3-26 Modules Revised February-2016
Figure 3-30. DIP Switches on APM
Table 3-6. APM DIP Switch Settings
S1 3 N/A
Standard PI Up
Current Modulated Densitometer Down
S2
1
2
Left
10 kΩ Pullup to 12 V dc
Up
Left No Pullup Resistor Down
2
Right
10 kΩ Pullup to 12 V dc
Up
Right No Pullup Resistor Down
S3
2
3
Left
10 kΩ Pullup to 12 V dc
Up
Left No Pullup Resistor Down
4
Right
10 kΩ Pullup to 12 V dc
Up
Right No Pullup Resistor Down
S4
Detector 2
Left
10 kΩ Pullup to 12 V dc
Up
Left No Pullup Resistor Down
Detector 1
Right
10 kΩ Pullup to 12 V dc
Up
Right No Pullup Resistor Down
S5
4
Left Pulse Output Up
Left Pulse Input Down
N/A Right N/A N/A
1
Descriptors (up/down/right/left) assume that module terminal blocks face upward and daughterboard is visible
(see Figure 3-30)
2