CG Drives & Automation 01-7318-01r1 Functional description 101
Analogue Comparator 1, Level Low [6113]
Sets the analogue comparator low level, with unit and range
according to the selected value in menu [6111].
Analogue Comparator 1, Type [6114]
Selects the analogue comparator type, i.e. Hysteresis or
Window type. See Fig. 79 and Fig. 80.
Analogue Comparator 1, Polarity [6115]
Selects how the selected value in [6111] should be handled
prior to the analogue comparator, i.e. as absolute value or
handled with sign. See Fig. 79
Example
See Fig. 79 and Fig. 80 for different principle
functionality of comparator features 6114 and 6115.
Fig. 79 Principle functionality of comparator features for
Type [6114] = Hysteresis ” and “Polar [6115]”.
Fig. 80 Principle functionality of comparator features for
Type [6114] =Window” and “Polar [6115]”.
CA2 Setup [612]
Analogue comparator 2, parameter group.
Analogue Comparator 2, Value [6121]
Function is identical to analogue comparator 1, value
[6111].
Analogue Comparator 2, Level High [6122]
Function is identical to analogue comparator 1,
level high [6112].
Default: 20.0 A
Range: Range as [6112].
Default: Hysteresis
Hysteresis 0 Hysteresis type comparator
Window 1 Window type comparator
Default: Unipolar
Unipolar 0 Absolute value of [6111] used
Bipolar 1 Signed value of [6111] used
6113 CA1 Level LO
Stp 20.0A
6114 CA1 Type
Stp Hysteresis
6115 CA1 Polar
Stp Unipolar
Type [6114]= Hysteresis
[6115] Unipolar
[6115] Bipolar
[6115] Bipolar
[6115] Bipolar
[6112] HI > 0
[6113] LO > 0
[6112] HI > 0
[6113] LO > 0
[6112] HI > 0
[6113] LO < 0
[6112] HI < 0
[6113] LO < 0
An.Value
[6111]
An.Value
[6111]
An.Value
[6111]
An.Value
[6111]
CA1
CA1
CA1
CA1
NOTE:
When “Unipolar “ is selected, absolute value of signal
is used.
NOTE:
When “Bipolar” is selected in [6115] then:
1. Functionality is not symmetrical .
2. Ranges for high/low are bipolar
Default: Torque
Selections: Same as in menu [6111]
Default: 20%
Range: Enter a value for the high level.
Type [6114] = Window
[6115] Unipolar
[6115] Bipolar
[6115] Bipolar
[6115] Bipolar
[6112] HI > 0
[6113] LO > 0
[6112] HI > 0
[6113] LO > 0
[6112] HI > 0
[6113] LO < 0
[6112] HI < 0
[6113] LO < 0
An.Value
[6111]
An.Value
[6111]
An.Value
[6111]
An.Value
[6111]
CA1
CA1
CA1
CA1
6121 CA2 Value
Stp Torque
6122 CA2 Level HI
Stp 20%