EasyManua.ls Logo

enraf Ensite Pro User Manual

Default Icon
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Instruction manual Ensite Pro Configuration Tool Page 1
Instruction manual
Ensite Pro
Configuration Tool
Version: 2.0
June 2001
Part no.: 4416.593
Enraf B.V.
P.O. Box 812
2600 AV Delft
Netherlands
Tel.: +31 15 2698600, Fax: +31 15 2619574
Email: Info@enraf.nl
http://www.enraf.com
Offices in: Netherlands - France - Germany - Russia - UK - USA - China - Singapore
Question and Answer IconNeed help?

Do you have a question about the enraf Ensite Pro and is the answer not in the manual?

enraf Ensite Pro Specifications

General IconGeneral
Brandenraf
ModelEnsite Pro
CategoryMeasuring Instruments
LanguageEnglish

Summary

Preface

Safety and Legal Information

Covers safety cautions, legal aspects, and provides contact information for assistance.

Introduction to Ensite Pro

Ensite Pro Overview

Describes Ensite Pro, its components (Entis Pro, CIU Plus, CIU Prime, Field Instrumentation), and key functions.

Ensite Pro Configuration Tool - General

Using the Ensite Pro Interface

Explains common buttons (OK, Cancel, Apply, Advanced) and methods for activating functions within the tool.

Configuration Procedure

Preparation and Procedure Steps

Details necessary preparations and lists the main steps for configuration.

Configuration Procedure - Details

Gauge Data Retrieval and Tank Configuration

Explains retrieving gauge data using ENSITE and configuring tanks, including strapping tables.

CIU Prime Configuration

Outlines the configurable parts of the CIU Prime, such as HostPorts and FieldPorts.

Configuration Procedure - Continued

CIU Plus Configuration and Linking Devices

Details CIU Plus configuration and the process of linking gauges, tanks, and CIUs.

Downloading Configuration Data

Explains the process of downloading the configuration to CIU Prime or Plus devices.

Starting Ensite Pro

Launching and Logging In

Describes how to start Ensite Pro and the initial login process with username and password.

Ensite Pro Main Interface

Site Selection, Help, and User Privileges

Covers selecting a site, accessing the help feature, and managing user privileges.

Site Management

Managing Sites: Copy, New, Select, Import, Delete

Details the operations for managing sites within Ensite Pro, including creating and managing site databases.

Global Settings

Setting Global Parameters: Dimensions, Pressure, Density

Explains setting global parameters like dimensions, ambient air pressure, and air density for data representation.

Ensite Pro Functionality Overview

Core Configuration Modules

Lists key modules: Select Site, Global Settings, Configure Data Inputs, Tanks, CIU Prime, and CIU Plus.

Ensite Pro Functionality - Advanced

Configuration Management and Data Viewing

Covers links, communication, download, upload, print, and diagnostic/tank/scan viewers.

System Maintenance and Support

Covers service notes, date/time settings, help access, and user privileges.

Configure Data Inputs

Managing Data Inputs

Describes operations for managing data inputs (Copy, New, Edit, Delete) within the Ensite Pro tool.

Configure Data Inputs - Gauge

Gauge Configuration using LOG File

Details configuring gauge settings using a LOG file and describes allowed gauge commands.

Configure Data Inputs - Gauge Details

Gauge Types, Commands, and Limitations

Describes gauge types, commands, general limits, and usage of BPM/RS232/485 cards.

Configure Data Inputs - Level

Level Measurement Settings

Details settings for level measurement, including enabling, resolution, and killed levels.

Configure Data Inputs - Water

Water Level Measurement Settings

Details settings for water level measurement, probe, dip, and manual overwrite.

Configure Data Inputs - Temperature

Temperature Measurement Settings

Details settings for temperature measurement, element type, and manual overwrite.

Configure Data Inputs - Density

Density Measurement Settings

Details settings for density measurement, HIMS, dip, and manual overwrite.

Configure Data Inputs - Pressure

Pressure Measurement Settings

Details settings for pressure measurement, absolute/relative, and manual overwrite.

Configure Data Inputs - Vapour

Vapour Temperature Measurement Settings

Details settings for vapour temperature measurement and manual overwrite.

Configure Data Inputs - Scan

Scan Configuration Settings

Details settings for scan configuration, including Field Display Indicator.

Configure Data Inputs - Tank Linkage

Linking Gauges to Tanks

Explains how a gauge is linked to a specific tank within the configuration.

Configure Tanks

Managing Tanks: Copy, New, Edit, Delete

Describes operations for managing tanks, including adding, copying, editing, and deleting tank entries.

Configure Tanks - Tank Properties

Tank Shape, Level Type, and Volume Correction

Details settings for tank shape, level type, volume correction, and tank status.

Configure Tanks - Product Settings

Product Name and Correction Factors

Details product name and various correction factors like API/ASTM, TC, VCF, and TCF.

Configure Tanks - Mass Calculation

Mass Calculation and VCF Details

Explains mass calculation options and Volume Correction Factor (VCF) details.

Configure Tanks - Vapour

Vapour Calculation Settings

Details settings for vapour calculation, including liquid-to-volume ratio and molar weight.

Configure Tanks - Shell

Shell Expansion and Insulation Settings

Details settings for tank shell calibration, CTSh correction, and insulation factor.

Configure Tanks - Flow

Flow Calculation Parameters

Details settings for flow calculation, including detection interval and damping factor.

Configure Tanks - Roof

Roof Configuration and Zone Settings

Details settings for roof configuration, including GOV and water volume for zones.

Configure Tanks - TCT

Tank Capacity Table (TCT) Configuration

Details TCT settings and related parameters like water volume and shell capacity.

Configure Tanks - Links

Tank Linkage Configuration

Explains how tanks are linked via CIU Prime/Plus to other components.

Configure CIU Prime

CIU Prime Overview and Management

Introduces CIU Prime, its board types, and management operations (Copy, New, Edit, Delete).

Configure CIU Prime - HostPort 1

HostPort 1 Communication Settings

Details settings for HostPort 1 on CIU Prime, including Modbus mapping and advanced options.

Configure CIU Prime - HostPort 2

HostPort 2 Communication Settings

Details settings for HostPort 2 on CIU Prime, including Modbus mapping and advanced options.

Configure CIU Prime - Advanced Settings

Advanced CIU Prime Parameters

Covers advanced settings like CIU emulation, MSU mode, stop bits, parity, and duplex mode.

Configure CIU Prime - Hot Standby

CIU Prime Hot Standby Configuration

Details settings for enabling and configuring hot standby for CIU Prime units.

Configure CIU Prime - FieldPorts

CIU Prime FieldPorts Configuration

Details settings for FieldPorts on CIU Prime, including type and poll strategy.

Configure CIU Prime - FieldPort Settings

FieldPort Communication Parameters (CIU-GPU/BPM-GPU)

Details specific communication settings for FieldPorts, including Baudrate and Mode.

Configure CIU Prime - FieldPort Details

FieldPort Communication Parameters and Failure Notes

Details parameters and notes on communication failures for FieldPorts.

Configure CIU Prime - Ambient

Ambient Temperature Settings

Details settings for ambient temperature scanning and broadcast.

Configure CIU Plus

CIU Plus Overview and Management

Introduces CIU Plus, its board types, and management operations (Copy, New, Edit, Delete).

Configure CIU Plus - HostPorts

CIU Plus HostPorts Configuration

Details settings for HostPorts on CIU Plus, including config name and type.

Configure CIU Plus - HostPort Settings

HostPort Communication and Modbus Settings

Details communication settings for HostPorts, including Modbus mapping and advanced options.

Modbus Settings - Data

Modbus Data Configuration

Details Modbus data orientation, start address, and record interval settings.

Modbus Settings - Tanks

Modbus Tank Selection for Communication

Describes selecting tanks for Modbus communication using available and user record lists.

Modbus Settings - Entities

Modbus Entity Configuration

Details configuring entities for Modbus communication, including type, size, scale, and offset.

Modbus Settings - Hot Standby

CIU Plus Hot Standby Configuration

Details hot standby settings for CIU Plus, including counterpart and connection options.

Modbus Settings - Hot Standby Details

Hot Standby Connection Diagrams

Illustrates connection diagrams for CIU Prime/Plus hot standby configurations.

Modbus Settings - FieldPort 1 & 2

FieldPort 1 & 2 Communication Settings

Details communication settings for FieldPorts 1 & 2, including baudrate, parity, and mode.

Configure Links - Data Inputs

Linking Data Inputs to Tanks

Explains how to link data inputs to tanks by dragging and dropping in the interface.

Configure Links - Tanks

Linking Tanks to CIU Prime FieldPorts

Explains how to link tanks to CIU Prime FieldPorts by dragging and dropping.

Configure Links - CIU Prime

Linking CIU Pluses to CIU Prime HostPorts

Explains how to link CIU Pluses to CIU Prime HostPorts by dragging and dropping.

Communication Setup

Setting Communication Parameters

Details settings for connecting to Ensis Pro, CIU Plus, CIU Prime, and PC Port settings.

Communication Setup - Monitoring

Monitoring Communication Activity

Describes how to monitor communication using the CIU Communication Monitor.

Download Configuration

Download Process and CRC Status

Explains the download process and CRC status for CIU Prime/Plus.

Download Configuration - Operations

Download Operations and Hot Standby

Details download operations, monitoring, INI-files, CRC checks, and hot standby procedures.

Upload Configuration

Upload Process and CRC Status

Explains the upload function and CRC status for CIU Prime/Plus.

Upload Configuration - Operations

Upload Operations and Hot Standby

Details upload operations, monitoring, CRC checks, and hot standby considerations.

Service Note

Using the Built-in Text Editor for Notes

Describes using the built-in text editor for storing site-specific information.

Set Date and Time

Setting CIU Prime/Plus Internal Clock

Details setting the internal clock and Daylight Saving Time for CIU Prime/Plus.

Print Configuration

Print Configuration Options

Describes options for printing configuration settings like site, CIU, tanks, and data inputs.

Print Configuration - Advanced

Print Preview and Printer Setup

Details using Print Preview, Print, and Printer Setup functions for configuration reports.

Show Diagnostic Data

Diagnostic Data Display and Database Management

Explains diagnostic data display, columns, analysis, and backup procedures.

Show Diagnostic Data - R/W Operations

Read/Write Data Operations for Entities

Details reading and writing data using entity selection within the diagnostic window.

Show Diagnostic Data - Clearing

Configuration and Novram Clearing Procedures

Explains procedures for clearing configuration and Novram data from CIU units.

Tank Viewer

Viewing Detailed Tank Information

Describes how to use the tank viewer to display single tank details.

Scan Viewer

Displaying Scan Sequence and Data Statuses

Explains the scan viewer, column descriptions, and measured data statuses.

Help

Accessing On-line Help

Describes how to access the on-line help feature for assistance.

User Privileges

User Management and Security

Details user management operations like adding, changing passwords, and deleting users.

Stopping Ensite Pro

Exiting the Configuration Tool

Explains how to stop and exit the Ensite Pro configuration tool.

Appendix A: Related Documents

Referenced Documentation

Lists related installation guides and manuals for Ensite Pro, CIU Prime, and CIU Plus.

Related product manuals