EasyManuals Logo

Epson RC700 Series Original Instructions

Epson RC700 Series
228 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #47 background imageLoading...
Page #47 background image
Installation 2. Installation
RC700 Series Rev.3 29
- Ensure the air flow around the supply and exhaust ports, and install the Controller
while leaving space from other equipment or walls as below.
* Keep the space about 200 mm or more on the top to maintenance.
(A)Flat mounting, (C)Rack mounting
100 mm
200 mm
Excluding the installation side
such as base table
Air flow of the fan
50 mm
50 mm
50 mm *
(Figure Flat mounting)
(B)Upright mounting
100 mm
200 mm
Excluding the installation side such as base table
Air flow of the fan
50 mm
50 mm *
50 mm
- Hot air with higher temperature than the ambient temperature (about 10 °C) comes out
from the Controller. Make sure that heat sensitive devices are not placed near the
outlet.
- Arrange the cables in front of the Controller so that you can pull the Controller forward.

Table of Contents

Other manuals for Epson RC700 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Epson RC700 Series and is the answer not in the manual?

Epson RC700 Series Specifications

General IconGeneral
ModelRC700 series
CategoryController
Programming LanguageSPEL+
Safety StandardISO 10218-1
TypeRobot Controller
Communication InterfaceEthernet, RS-232, USB
Operating Temperature0°C to 45°C (32°F to 113°F)
Humidity20% to 80% (non-condensing)
Number of controllable robots4