AT Commands Modem Terminated 154
ATS6 Blind Dial Delay Control
ATS7 Completion Connection Timeout
Parameter:
<value>:
<value> Description
0-127 Supported values
8 Formatting character
Default setting
Description: Defines the number of seconds to wait before call-addressing when a dial tone is not
detected. This command is ignored by the infrared modem and is included for
compatibility reasons only.
Set command: ATS6=[<delay>]
Read command: ATS6? Displays the current <delay> setting.
Test command: ATS6=? Shows if the command is supported.
Test command
response:
S6: (list of supported <delay>s)
Parameter:
<delay>:
<delay> Description
2 Wait 2 seconds before blind dialling
Default setting
2-255 Number of seconds to wait before blind dialling
Description: Defines the maximum time allowed between completion of dialling and the
connection being established. If this time is exceeded, the connection is aborted.
Set command: ATS7=[<tmo>]
Read command: ATS7? Displays the current <tmo> setting.
Test command: ATS7=? Shows if the command is supported.
Test command
response:
S7: (list of supported <tmo>s)
Parameter:
<tmo>:
<tmo> Description
50 Timeout value in seconds
Default setting
1-255 Timeout value in seconds