AT Commands Modem Terminated 180
AT+FPHCTO Phase C Timeout
AT+FPTS Page Transfer Status
AT+FREV Request Product Revision Identification
Description: Determines how long the TAE will wait for a command after reaching the end of data
when transmitting in Phase C.
Set command: AT+FPHCTO=<value>
Read command: AT+FPHCTO? Displays the current <value> setting.
Test command: AT+FPHCTO=? Shows if the command is supported.
Test command
response:
+FPHCTO: (list of supported <value>s)
Parameter:
<value>:
<value> Description
0-255 Timeout setting, in 100 ms units
30 Timeout after 3 seconds
Default setting
Description: Sets the post-page transfer response.
Set command: AT+FPTS=<ppr>
Read command: AT+FPTS? Displays the current <ppr> setting.
Test command: AT+FPTS=? Shows if the command is supported.
Test command
response:
+FPTS: (list of supported <ppr>s)
Parameter:
<value>:
<ppr> Description
0 Page good
Default setting
1 Page bad; retrain requested
2 Page good; retrain requested
Description: Returns the version, revision level, or other information related to a Class 2 device.
Read command: AT+FREV?
Example: AT+FREV
<Revision ID>
OK