EasyManua.ls Logo

ESAB Aristo U8 - 7.3 Weld Data Settings; 7.4 Function Explanations

ESAB Aristo U8
72 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
-- 2 8 --
bi09d1e2
7.3 Settings in the weld data setting menu
Settings for dip--/spray arc alternative pulsing see chapter 3.1.1 and 3.1.2.
Settings Setting range In steps of: Values after
reset
Synergic
depend -
ent
Adjust--
able in
synergic
Phase Primary or
secondary
-- Primary x
Phase weld time 0--2.50s 0,01 0.05 (secondary)
0.22 (primary)
x
7.4 Function explanations for settings
The function explanations for settings for Superpulse and other MIG/MAG--welding
see pages 17--20 .
7.4.1 Phase
In this function you can choose between primary or secondary.
High data is set in primary and low data is set in secondary.
The settings are used to determine whether primary or secondary data should be
available for editing. It also determines which data is affected in measuring and
remote modes. T he wire feed speed shown in the measure image shows the speed
in the selected phase. However, the voltage, current and weld output are based on
the measurement under both phases.
You can choose different synergy in the primary and secondary phases. Note that
you must make the same selection in both primary and secondary when the same
synergy is required.
-- Phase is set in the main menu.
7.5 Wire feed unit
Use only wire feed unit Feed 3004, Aristot with MIG SUPERPULSE.
Precaution s!
When using MIG SUPERPULSE there is a high load on the wire feed unit. To ensure
that the reliability o f the feed unit is not endangered follow the limits in the diagram
below.
GB

Table of Contents

Related product manuals