-- 6 1 --
bi09d1e2
Error
code
Description
9 --15V power supply, (power unit)
The supply voltage is too high or too low.
Action: Call a service engineer.
9 +20V power supply, (wire feeder)
The supply voltage is too high or too low.
Action: Call a service engineer.
10 +15VB power supply, (Mig 4500i)
The supply voltage is too high or too low.
Action: Call a service engineer.
10 +24VB power supply, (Mig 4000i/Mig 5000i)
The supply voltage is too high or too low.
Action: Call a service engineer.
11 Wire speed
The wire speed is deviating from the preset value.
When this error occurs, the wire feed process stops.
Action: Call a service engineer.
12 Communication error (warning)
The load on the system’s CAN bus is too high at the moment.
The power source/wire feeder might have lost contact with the controller .
Action: Check the equipment to make sure that everything is properly connected.
If the error persists, call a service engineer.
14 Communication error
The system’ s CAN bus has temporarily stopped working due to the load being too high.
The current welding process stops.
Action: Check the equipment to make sure that everything is properly connected. It will
be necessary to turn off the power supply to reset the system. If the error persists, call a
service engineer.
15 Messages lost
The microprocessor cannot process incoming messages at the required speed, and
information has been lost.
Action: It will be necessary to turn off the power supply to reset the system. If the error
persists, call a service engineer .
17 Lost contact
The controller has lost contact with the wire feeder.
The current welding process stops.
Action: Check the cables. If the error persists, call a service engineer .
18 Lost contact
The controller has lost contact with the power unit.
The current welding process stops.
Action: Check the cables. If the error persists, call a service engineer .
19 Memory error in battery--powered data memory RAM
The battery has no power .
Action: Turn off the mains power supply to reset the system. Reset the controller . The
settings will be in English with MIG/MAG, DIP/SPRAY, Fe, CO2, 1.2 mm.
If the error persists, call a service engineer.
GB