Ethos v1.5.7 and X18, X20 series User Manual
XOR (Exclusive OR)
The condition is True if only one of the sources selected in Value 1, Value 2 …
Value(n) are true (i.e. ON).
Timer generator
The logical switch toggles on and off continuously. It switches on for time ‘Duration
active’, and off for time ‘Duration inactive’.
Sticky
The Sticky function is latched on (i.e becomes True) when the’Trigger ON condition’
switches from False to True, and holds its value until it is forced to False when the
‘Trigger OFF condition’ switches from False to True. This can be gated by the optional
‘Active condition’ parameter. This means that if the active condition is True, then the
logical switch output follows the Sticky function's condition. However, if the active
condition is False, then the logical switch output is also held False.