EasyManua.ls Logo

Fibocom L860-GL - Page 115

Fibocom L860-GL
254 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Reproduction forbidden without Fibocom Wireless Inc. written authorization All Rights Reserved.
FIBOCOM L860 AT Commands User Manual Page 115 of 254
unchanged. The MT responds with +CUSATW : <profile_storage>,<conflict_profile> where
<profile_storage> refers the conflicting profile followed by the final result code +CME ERROR: 3
(Operation not allowed). The rules for detecting conflicts are defined in 3GPP TS 31.111 [92].
Successful execution of the command does not result in any information response.
Command
Description
Set [Function]
Set command without parameters resets stored TE and MT profiles to their default
values. Adding parameter <profile_storage> to the AT command resets only the
referred storage to its default value. Execution command issued with accompanied
parameter <profile>, stores the given <profile> to non-volatile memory in the MT.
[Syntax]
AT+CUSATW[=<profile_storage>[,<profile>]]
[Response/Action]
+CUSATW: <profile_storage>,<profile>[<CR><LF>+cusatw:
<profile_storage>,<profile>
[...]]
or
+CME ERROR: <err>
Read
N/A
Test [Function]
Test command returns values supported as a compound value.
[Syntax]
AT+CUSATW=?
[Response/Action]
+CUSATW: (list of supported <profile_storage>s)
OK
Parameters <profile_storage>
Is an integer type.
0 TE. Refers profile storage for the facilities supported by the TE. Default value is a
blank profile with all bits set to zero.
1 MT. Refers profile storage for the facilities to be
supported by MT, which can be a subset of the default MT facilities (see +CUSATW).

Table of Contents