FIBOCOM L860 AT Commands User Manual Page 55 of 254
Command Description
Test [Function]
This command returns the supported values.
[Syntax]
AT+GTWAKE=?
[Response/Action]
+GTWAKE: (0,1)
OK
Parameters <mode>
0 :wake host is disable.
1 :wake host is enable.
Example AT+GTWAKE=1
OK
AT+GTWAKE?
+GTWAKE: 1
OK
AT+GTWAKE=?
+GTWAKE: (0,1)
OK
4.2.6 +MSTART, Start message notification
This command can Enable/Disable the module output start message when power up.
Command Description
Set [Function]
This command is used to set the start message when power up.
[Syntax]
AT+MSTART=<at start>,<sim ready>
[Response/Action]
OK
or
ERROR
Read [Function]
This command returns the current status.