FIBOCOM L860 AT Commands User Manual Page 35 of 254
Command
Description
[Response/Action]
OK
or:
+CME ERROR: <err>
Read N/A
Test
N/A
Parameters <value>
0 CONNECT result code given upon entering online data state:
Dial tone detection - Disabled
Busy detection - Disabled
1 CONNECT <text> result code given upon entering online data state:
Dial tone detection - Disabled
Busy detection - Disabled
2 CONNECT <text> result code given upon entering online data state:
Dial tone detection - Enabled
Busy detection - Disabled
3 CONNECT <text> result code given upon entering online data state:
Dial tone detection - Disabled
Busy detection - Enabled
4 CONNECT <text> result code given upon entering online data state:
Dial tone detection - Enabled
Busy detection Enabled
The default value is 4.
Example ATX3
OK
ATX4
OK
4.1.5 S, Bit Map Registers
This command reads/writes values of the S-registers. The Modem supports this command for various S
values, according to official specifications (ITU-I, ETSI, or manufacturer specific).

Table of Contents