9.1.22 +XSYSTRACE, Configure System Trace
This command allows to configure system trace port, mode.
Command Description
Set
[Function]
Execution command allows to configure system trace port, mode
[Syntax]
AT+XSYSTRACE=<mode>,["<master>=<port>[;<master>=<port>[;]]"],["<master>=<co
nfig>[;<master>=<config>[;]]"],["[oct=<oct_mode>][;pti1=<pti1_mode>][;pti2=<pti2_mod
e>]"]
[Response/Action]
OK
or
CME ERROR: <error>
Test [Function]
Test command returns list of supported <mode>s],[list of supported "<master>
=<port>"s],[list of supported "<master>=<config>s]",[list of supported oct=<oct_
mode>],[;pti1=<pti1_mode>],[;pti2=<pti2_mode>"s].
[Syntax]
AT+ XSYSTRACE =?
[Response/Action]
+XSYSTRACE:[list of supported <mode>s],[list of supported "<master>=<port>"s],[list
of supported "<master>=<config>s]",[list of supported
oct=<oct_mode>][;pti1=<pti1_mode>][;pti2=<pti2_mode>"s]
OK
Limitation
The total length of parameters in set command cannot exceed 400 characters due to
C-AT parser limitation. For set command with total parameter length exceeding 400
characters, multiple set commands by splitting the parameters can be issued.
Example
at+xsystrace=0,"bb_sw=1","bb_sw=sdl:th,tr,st,pr,mo,lt,db,li,sy|lte_stk:0x02,0x83FFFFF
F|ims:1|lte_stk:0x01,0xFFFFFFFF,0xFFFFFFFF,0xFFFFFFFF,0xFFFFFFFF","oct=4;o
ct_fcs=16"