Reproduction forbidden without Fibocom Wireless Inc. written authorization – All Rights Reserved.
FIBOCOM L860 AT Commands User Manual Page 221 of 254
Parameters <cid> A numeric parameter which specifies a particular PDP context definition (see
the +CGDCONT and +CGDSCONT commands)
Example AT+CGDCONT?
+CGDCONT: 1,"IP","CMNET","172.29.107.202",0,0
+CGDCONT: 2,"IP","","0.0.0.0",1,1
+CGDCONT: 3,"IP","CMNET","0.0.0.0",0,0
+CGDCONT: 4,"IP","CMNET","0.0.0.0",0,0
+CGDCONT: 6,"IPV6","CDOE","0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0",0,0
OK
AT+CGCMOD=1,1,
OK
AT+CGCMOD=1,1,6
OK
AT+CGDCONT?
+CGDCONT: 1,"IP","CMNET","172.29.107.202",0,0
+CGDCONT: 2,"IP","","0.0.0.0",1,1
+CGDCONT: 3,"IP","CMNET","0.0.0.0",0,0
+CGDCONT: 4,"IP","CMNET","0.0.0.0",0,0
+CGDCONT: 6,"IPV6","CDOE","0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0",0,0
OK
AT+CGCMOD=?
+CGCMOD: (1,2,3,4,6)
Reference 3GPP TS 27.007
11.2.15 +CGDATA,Enter Data State
This execution command causes the MT to perform whatever actions are necessary to establish
communication between the TE and the network using one or more GPRS PDP types. This may include
performing a GPRS attach and one or more PDP context activation. If the parameters are accepted, MT
displays the intermediate result code CONNECT on TE and enters the online data state; thereafter data
transfer may proceed. No other commands following +CGDATA in the command line will be processed.
Note: After data transfer is complete, the MT re-enters the command state and the final result