FIBOCOM L860 AT Commands User Manual Page 56 of 254
Command Description
[Syntax]
AT+MSTART?
[Response/Action]
+MSTART: <at start>,<sim ready>
OK
Test [Function]
This command returns the supported values.
[Syntax]
AT+MSTART=?
[Response/Action]
+MSTART: ((list of supported <at start>),(list of supported <sim read>))
OK
Parameters <at start>
0: Do not output “AT command ready” from UART
1: Output “AT command ready” from UART (default value)
<sim ready>
0: Do not output “+SIM READY” after SIM init OK
1: Output “+SIM READY” after SIM init OK (default value)
Notes:
AT command ready” can not output from USB port even if set to 1. “+SIM
READY” can output from UART and USB port according to setting.
Example AT+MSTART=?
+MSTART: (0-1,0-1)
OK
AT+MSTART=1,1
OK
AT+MSTART?
+MSTART: 1,1
OK