FIBOCOM L860 AT Commands User Manual Page 162 of 254
Command Description
<index1>,<format>,<oper1>[,<GSM_AcT1>,<GSM_Compact_AcT1>,<UTRAN_AcT1
> ,<UTRAN_AcT1>][<CR><LF>+CPOL: <index2>,<format>,<oper2>
[,<GSM_AcT2>,<GSM_Compact_AcT2>,<UTRAN_AcT2> ,<UTRAN_Ac
T1>] […]]
OK
or
+CME ERROR: <err>
Test [Function]
The Test command displays the entire index range supported by the SIM.
[Syntax]
AT+CPOL=?
[Response/Action]
+CPOL: (list of supported<index>s),(list of supported<format>s)
OK
or:
+CME ERROR: <err>
* Index range is SIM dependent
Parameters <indexn> Order number of network operator in the SIM preferred operator list
<format> Defines the <oper> format:
0 Long alphanumeric format (up to 16 characters) (default)
1 Short alphanumeric format (up to 8 characters)
2 Numeric
<oper> Name of the network operator
string type; <format> indicates if the format is alphanumeric or numeric (see +COPS)
<GSM_AcTn> GSM access technology
0 access technology not selected
1 access technology selected
<GSM_Compact_AcTn> GSM compact access technology
0 access technology not selected
1 access technology selected
<UTRA_AcTn> UTRA access technology
0 access technology not selected
1 access technology selected

Table of Contents