Chapter 5: System Software
5-15
Container Finish Functions Group
Bulged End Status
Activates or deactivates Bulged End detection. Bulged End
detection is based on the difference between the height of the
container with a properly sealed lid and the height of the container
with an improperly sealed or bulged lid.
Missing Lid Status
Activates or deactivates Missing Lid detection. Missing Lid
detection utilizes proximity or optical sensors to detect the
presence or absence of the lid.
Down Can Status
Activates or deactivates Down Can Detection. Down Can detection
uses a optical sensor to detect cans that have fallen over from their
upright position.
Diameter Missing Lid Status
Activates or deactivates Diameter Missing Lid detection. Diameter
Missing Lid detection is based on the difference between the
diameter of the container without a lid and the diameter of the
container with a lid.
External Reject Status
Activates or deactivates the External Reject function. When
activated the FT-50 will accept the reject signal from an outside
inspection source and activate the rejector.
Width at Down Can
The container diameter at the point where it intersects the Down
Can Sensor Beam. This option applies only to Down Can detection.
Height of Can
The height of the container. This option applies only to Down Can
detection.