FT-50 Fill Level Inspector Service Manual
10-10
LED Definitions
Section 1, Bank 1: S2-7 = Closed/S2-8 = Closed
Section 1, Bank 2: S2-7 = Closed/S2-8 = Open
This section is used when the Label Inspection Option is installed
in your FT-50. For More information refer to your Label Inspection
Manual.
LED 1 Fault Error Present: The LED is on when there is a Fault
Alarm or other error in the system.
LED 2 Reject Pulse: Flashes one time for each container rejected.
LED 3 High Res Encoder Pulse: Flashes once for each pulse.
LED 4 Not used in this conguration.
LED 5 Slat Backup Sensor: Indicator lights when the sensor is
activated or when sensor is blocked.
LED 6 Bulged End Trigger: Indicator lights when the High Cap
sensor is activated or when sensor is blocked.
LED 7 Missing Lid Trigger: Indicator lights when the Missing Cap
sensor is activated or when lid is present.
LED 8 Inspect Trigger: Indicator lights when the Inspection Trigger
sensor is activated or when the sensor is blocked.
LED 9 AC Power Low: Indicator lights when the input AC power to
the FT-50 is too low to operate satisfactorily (below 70 VAC).
LED 10 +5 VDC Power Low: Indicator lights when the +5 VDC power
supply is too low to operate satisfactorily (below 4.85 VDC).
Indicator is also on when the Reset button is pressed.
LED 11 Detector: Used to get a coarse calibration setting for the Solid
State Detector.
Industrial Dynamics Company, Ltd. Document 40255-0600