Chapter 10: Controller Board Dip Switches and LEDs
10-11
Section 2, Bank 1: S2-7 = Open/S2-8 = Closed
Section 2, Bank 2: S2-7 = Open/S2-8 = Open
LED 1 Fault Error Present: The Indicator lights when there is a Fault
Alarm or other error in the system.
LED 2 Reject Pulse: Flashes one time for each container rejected.
LED 3 Low Resolution Encoder Pulse: Flashes once for each pulse.
LED 4 Not used in this configuration.
LED 5 Not used in this configuration.
LED 6 External Reject: Flashes one time for each input received from
an external source requesting the next container to be rejected.
LED 7 Not used in this configuration.
LED 8 Inspect Trigger: Indicator lights when the Inspection Trigger
sensor is activated or when sensor is blocked.
LED 9 AC Power Low: Indicator lights when the input AC power to the
FT-50 is too low to operate satisfactorily (below 70 VAC).
LED 10 +5 VDC Power Low: Indicator lights when the +5 VDC power
supply is too low to operate satisfactorily (below 4.85 VDC).
Indicator is also on when the RESET button is pressed.
LED 11 Detector: Used to get a coarse calibration setting for the
Scintillation Detector.
LED 1 Inlabeler Sensor Input 1
LED 2 Inlabeler Sensor Input 2
LED 3 Inlabeler Sensor Input 3
LED 4 Inlabeler Sensor Input 4
LED 5 Inlabeler Sensor Input 5
LED 6 Container Present
LED 7 System Timing
LED 8 Inspect Trigger: Indicator lights when the Inspection Trigger
sensor is activated or when sensor is blocked.
LED 9 AC Power Low: Indicator lights when the input AC power to the
FT-50 is too low to operate satisfactorily (below 70 VAC).
LED 10 +5 VDC Power Low: Indicator lights when the +5 VDC power
supply is too low to operate satisfactorily (below 4.85 VDC).
Indicator is also on when the Reset button is pressed.
LED 11 Detector: Used to get a coarse calibration setting for the
Scintillation Detector.
Industrial Dynamics Company, Ltd. Document 40255-0600