Chapter 5: System Software
5-31
# of Container Types
The maximum number of different container types that will be
inspected by this FT-50. The maximum number allowed is deter-
mined by available system memory. The value entered for this
function determines the number of Current Container Types
available.
Current Container Type
A set of stored system parameters for a particular container type.
This function allows you to configure the FT-50 for a specific
container and then save the configuration to memory for recall
when switching between container types. When you switch
production between container types, you need only select that
container type from the Current Container Type list, and all
settings are loaded.
The number of container types is determined by the # Of
Container Types function, and the name for each container type is
entered in the Container Text function.
Fill Level
Prepares the FT-50 software for fill level inspection by inserting the
necessary options into the software. When set to Not Present it
removes the options necessary for fill level inspection from the
software.
This function does not activate or deactivate fill level inspection, it
only readies the machine. To turn fill level inspection on or off you
must use the Fill Level Status function.
Underfill Text
Allows you to create a custom name for the Underfill Inspection
Option. Any instance in which “Underfill” would have appeared
in the software, is replaced by the custom label you created. The
following options are effected:
Underfill Status
Total Underfill
Reset Underfill
Alarm Underfill
Underfill Text
Industrial Dynamics Company, Ltd. Document 40255-0600

Table of Contents