Chapter 5: System Software
5-23
System Functions Group
Current Container Type
The container type that is currently being inspected. This function
is only available if machine is configured for multiple container
types.
To select the Current Container Type:
1. Press Key 5 until CURRENT CONTAINER TYPE appears.
2. Press the Arrow Key until the desired container type appears.
Last Reject Detected
The type of failure that caused the most recent reject container. The
failure classification can be any of the inspection capabilities
installed and active on your system.
Beacon Status
Determines the operational status of the warning beacon. There are
three status choices:
On: the beacon will flash once for each rejected container and
continuously when a diagnostic error occurs. The beacon will
stop flashing when the diagnostic error is cleared.
Off: The beacon will flash once for each rejected container.
High Priority Only: The beacon will flash once for each rejected
container and continuously when a high priority diagnostic
error occurs. The beacon will stop flashing when the diagnostic
error is cleared.
Line Speed (cpm)
The speed of the production line measured by cpm (containers per
minute). The measurement is the number containers that intercept
the FT-50’s trigger beam in 60 seconds. To calculate cpm from cph
(containers per hour) use the following formula:
cph
60
---------
cpm=
Industrial Dynamics Company, Ltd. Document 40255-0600