FT-50 Fill Level Inspector Service Manual
5-28
Can Width At Trig
The container’s width in millimeters at the point where it inter-
cepts the trigger beam as it travels on the conveyor. This value is
required to establish the proper time for the rejector to actuate so
the centerline of the rejector pad impacts the centerline of the
container.
Maximum Can Diameter
The maximum diameter of the largest container that is run on this
production line.
Maximum Line Speed
The maximum production speed of the conveyor defined as cpm
(containers per minute).
Maximum Conveyor Speed
The maximum production speed of the conveyor defined as mpm
(meters per minute).
Change Password
Allows you to enter a three (3) digit password. When the Password
Option is active, you must enter the code to enter the Calibrate
Mode. The default password is 222. To change the password, do
the following:
1. Remove the FT-50’s cover to gain access to dip switch S1-8.
2. Close dip switch S1-8. S1-8 is located on the processor card.
Note
The Change Password function will not appear in the display
unless the dip switch S1-8 is closed. To disable the password
protect function, close switch S1-8.
3. Press Key 5 until SYSTEM DISPLAY appears and then press
the Arrow Key to enter the Calibrate Mode.
4. Press Key 5 until CHANGE PASSWORD appears and then
press the Arrow Key for the ENTER PASSWORD prompt to
appear.
5. Use the numbered keys (keys 1-6) to enter a number for each of
the 3 digits. Record the password for future reference.
Industrial Dynamics Company, Ltd. Document 40255-0600