FT-50 Fill Level Inspector Service Manual
4-16
Software Configuration
Before you begin configuring the FT-50 software, complete the
mechanical configuration as explained in the previous section.
To configure the FT-50 software you must perform the following
procedures:
• Calibrate the Encoder and the Rejector Timing.
• Configure the Inspection Looktime Gate
• Configure the Gamma Threshold
If your FT-50 contains the following options, you must also
complete these additional procedures:
• Configure the Missing Lid Function
• Configure the Bulged End Function
• Configure the Diameter Missing Lid Function
• Configure the Down Can Function
Calibrating the Encoder and Rejector Timing
The encoder calibration and rejector timing are complex proce-
dures that require high accuracy. Because of the nature of the these
procedure, we have included them in a separate chapter, Chapter
6: Encoder Calibration and Rejector Timing Procedures.
Proceed to Chapter 6 and complete the required procedure. When
finished, return to this chapter and proceed to Configuring the
Inspection Looktime Gate.
Industrial Dynamics Company, Ltd. Document 40255-0600