FT-50 Fill Level Inspector Service Manual
5-42
Diagnostic Error Codes Listing
The following list contains the FT-50 error codes. Depending upon
your machine type, some of these errors may not apply to your
FT-50. For complete error descriptions, see Chapter 8.
0 No Diagnostic Error
* 2 Rejector Status Is Off
5 Consecutive Reject Queue Error
6 Consecutive Reject Timing Error-Missed Encoder Pulse
8 EEPROM Cannot Be Erased. Check S11 Or Replace U29
9 Write To Eeprom Unsuccessful. Check S11 Or Replace U29
10 Fill Level Detection Error-Exceeded Consecutive Reject Limit
11 Missing Lid Detection Error-Exceeded Consecutive Reject Limit
12 Bulged End Detection Error-Exceeded Consecutive Reject Limit
13 Gamma Counts Below Reject Threshold Error
14 Gamma Detector Error
15 Missing Lid Sensor Error
16 Trigger Beam Error
17 Encoder Sensor Error
18 Slat Rejector Backup Sensor Is Blocked
22 Encoder Pulse Missed
23 Extra Encoder Pulse Detected
24 High Resolution Encoder Minimum Distance Error
25 High Resolution Encoder Minimum Time Error
* 27 High Resolution Encoder Failure
* 33 Down Can Detection Error-Exceeded Consecutive Reject Limit
* 34 Down Can Detection Error-False Trigger
* 46 Consecutive External Reject Alarm
47 Encoder Resolution Too Low
* 48 AC Input Voltage Low, Brownout Detected
* 49 User Defaults Closed For One Or More Settings
50 System Defaults Loaded For One Or More Settings
51 Container Passed With No Encoder Pulses
52 Container Less Than 10 Ms
53 Reject Watchdog Detected Queue Error
Industrial Dynamics Company, Ltd. Document 40255-0600