Chapter 10: Controller Board Dip Switches and LEDs
10-9
LED Configurations
The LED assignments below are listed by the Section and Bank.
Selecting a Section and Bank is controlled by Dip Switches S2- 7
and S2-8. The multiple banks are necessary to handle the various
options available for the FT-50.
LED Logic
The standard detection logic for the LEDs is on when the sensor is
blocked and off when a sensor is clear. Some options, such as High
Cap Detection, use reverse detection logic. When reverse detection
logic is used the LED is off when the sensor is blocked and on
when the sensor is clear.
Refer to the System Configuration Sheet located inside the cover of
your FT-50 for you specific configuration.
LED
Section 1, S27= close
Bank 1, S28= close
Section 1, S27= close
Bank 2, S28= open
Section 2, S27= open
Bank 1, S28= close
Section 2, S27= open
Bank 2, S28= open
1 Diag Error Label 1 Remote Clr Inlabeler 1
2 Reject Pulse Label 2 Broken Slat or Batch Rej Inlabeler 2
3 Hi Res Encoder Label 3 Low Res Encoder Inlabeler 3
4 Low Foam Label 4 Optical FL Inlabeler 4
5 Downcan/Smash Label 5 X-ray Failure Inlabeler 5
6 Bulged/High Cap Label 6 Extrn or FSR 1 Cntr Present
7 Missing Cap/Lid Label 7 Slat Backup or Reject Verify System Timing
8 Trigger Label 8 Trigger Trigger