FT-50 Fill Level Inspector Service Manual
5-22
Inspect Trig To C/L Rej
The distance in millimeters from the centerline of the inspection
trigger beam to the centerline of the rejector pad. This value is
required to establish the proper time for the rejector to actuate so
the centerline of the rejector pad impacts the centerline of the
container.
Rejector Reaction Delay
The response time in milliseconds between when the container
fails inspection and when the reject signal is sent to the rejector.
The FT-50’s processor uses this value to establish a lead time for
the rejector pulse to compensate for the inertia of the rejector
mechanism.
Industrial Dynamics Company, Ltd. Document 40255-0600